Precision Cleaning of Connecting Rods

  • Component Name : Connecting rod
  • Present method : Old conveyorised spray cleaning
  • Production rate : 2500 pieces / shift
  • Problem faced : Millipore result not achieved.
  • Input contamination level : 10 – 15 mg
  • Expected output cleanliness : 1 – 2 mg

Solution provided by GALA :
Multi Stage Conveyorised Spray Washing System

Cleaning Cycle –

  • First Stage : De-magnetiser
  • Second Stage : Spray washing 8 to 10 bar pressure with 50 micron filtration
  • Third Stage : Spray rinsing 4 to 5 bar pressure with 25 micron filtration
  • Fourth Stage : Hot air drying at 80 to 100 degree centigrade