- Component Name : Connecting rod
- Present method : Old conveyorised spray cleaning
- Production rate : 2500 pieces / shift
- Problem faced : Millipore result not achieved.
- Input contamination level : 10 – 15 mg
- Expected output cleanliness : 1 – 2 mg
Solution provided by GALA :
Multi Stage Conveyorised Spray Washing System
Cleaning Cycle –
- First Stage : De-magnetiser
- Second Stage : Spray washing 8 to 10 bar pressure with 50 micron filtration
- Third Stage : Spray rinsing 4 to 5 bar pressure with 25 micron filtration
- Fourth Stage : Hot air drying at 80 to 100 degree centigrade