Skip links

Precision Cleaning of Vane

Washing and cleaning of non metallic parts by using compound GEW 2250L and GEW 2220L

  • Millipore Requirement : <1 mg
  • Component : Plastic Vane
  • Input Contamination : Lapping Paste
  • Challenge : To achieve Millipore value of 1 mg from input gravimetric contamination level of >250 mg and maintaining bath purity by separation of lapping paste for consistent results

Solution provided by GALA:

  • Compound Used : Specially developed alkaline compound for nonmetallic parts
  • Millipore achieved : Output gravimetric contamination <1 mg achieved
  • First Stage : Spray Cleaning
  • Second Stage : Ultrasonic Cleaning 1
  • Third Stage : Ultrasonic Cleaning – 2
  • Fourth Stage : Immersed Flood Rinsing
  • Fifth Stage : Hot Air Drying
  • Advantages : Reduced running cost by 50%