Skip links

Removal of Lubricant, Oil from Steel Wire

  • Component Name : Connecting rod
  • Present method : Old conveyorised spray cleaning
  • Production rate : 2500 pieces / shift
  • Problem faced : Millipore result not achieved.
  • Input contamination level : 10 – 15 mg
  • Expected output cleanliness : 1 – 2 mg

Solution provided by GALA:
Multi Stage Ultrasonic Cleaning Machine

  • First Stage : Ultrasonic cleaning with alkaline chemical
  • Second Stage : Ultrasonic rinsing
  • Third Stage : Hot air drying