- Component Name : Connecting rod
- Present method : Old conveyorised spray cleaning
- Production rate : 2500 pieces / shift
- Problem faced : Millipore result not achieved.
- Input contamination level : 10 – 15 mg
- Expected output cleanliness : 1 – 2 mg
Solution provided by GALA:
Multi Stage Ultrasonic Cleaning Machine
- First Stage : Ultrasonic cleaning with alkaline chemical
- Second Stage : Ultrasonic rinsing
- Third Stage : Hot air drying